Non-contact intelligent fault detection system for railway power transmission line

model:DX-WPS100-GZ03

Online Inquiry+8618926454155


Product details

Non-contact intelligent fault detection system for railway power transmission line

model:DX-WPS100-GZ03

1、 Demand analysis

The electric power through (self closing) line erected along the railway line is an important part of the electrified railway. The railway erection environment is complex and the terrain is changeable. The through line mostly adopts the mixed mode of overhead lines and cables. Due to the exposure of overhead lines and the aging of cable line equipment, failures are inevitable during the operation. Once failures occur, the railway signaling devices will not operate normally, thus affecting the normal transportation of the railway. Therefore, when a fault occurs, you should master the fault information as soon as possible and eliminate the fault.

At present, as there is no mature fault monitoring and management system for the railway through line, our company has developed a set of through line fault monitoring and management system that can directly display the line status and fault conditions, which is of great significance to improve the reliability of railway operation.


2、 Working principle

The fault traveling wave is transmitted from the fault point to both ends of the line in the form of electromagnetic wave through the air medium between the railway catenary and the earth. The basic principle of non-contact traveling wave is to use special antenna sensor to receive electromagnetic wave signals, so as to realize non-contact acquisition of voltage and current fault traveling wave of railway catenary. The distributed multi terminal ranging algorithm is used to calculate the location of the fault point. The ranging accuracy can reach within 100 meters. The tower level fault location can be achieved. The device has no electrical connection with the line and can be installed and maintained live.


3、 Product features

(1) Basic configuration of intelligent fault detection system: main control unit, non-contact fault location monitoring unit, communication unit, solar power supply unit, mounting bracket and auxiliary materials.

(2) The non-contact intelligent fault detection system for railway power through line is applicable to the first level railway power through line and railway power integrated through line, and fully supports the application of overhead/cable/hybrid line types.

(3) Convenient installation: the detection device (terminal) is non-contact design, self powered, 4G communication transmission with the main station, no electrical connection with the power line, and no power cut is required for installation or maintenance.

(4) Wide application environment: applicable to different types of overhead lines, cable lines, overhead cable hybrid lines, and complex line structures such as T connection.

(5) High ranging accuracy and accurate positioning: It is the first in China to adopt non-contact distributed multi segment ranging principle products, and the comprehensive application of a variety of advanced technologies recognized by experts, with ranging accuracy up to 100 meters.

(6) Fault type identification: through distributed collection and multi waveform comprehensive analysis, identify lightning strike fault and non lightning strike fault, fault and instantaneous flashover fault caused by tree branches and birds, and give early warning for lightning strike area.

(7) Real time geographic information of main station fault: high-precision real-time release of geographic information map of fault occurrence, and visual display of fault location.

(8) Super capacity cloud service center master station: users can share data from computer clients, mobile phones or tablets through the master station data push without installing master station software.

(9) Technology, positioning: distributed multi terminal ranging algorithm, space voltage and current traveling wave broadband detection technology, dynamic wave speed adaptive technology, multi acquisition point redundant ranging technology

(10) The data is complete and the functions are powerful: the man-machine interface of account management is intuitive and friendly, the geographical location distribution map is displayed in real time, the fault query and retrieval of the management area/line is convenient, the analysis of multiple waveform diagrams is comprehensive and detailed, and the analysis of fault types such as lightning strike, non lightning disturbance, etc.

(11) Simple application: data is published to mobile phones, tablets and clients


4、 Engineering case


Contact us

Shenzhen Dinsee Smart Technology Co.,Ltd
Tel:0755-21612345?Mobile&Whatsapp:+8618926454155
Fax:0755-21612345Whatsapp:+8618926454155E-Mail:business@szdx.com
Address: Building 2,xiangyuer Industry Part,NO.8 Longsheng Road,Longgang District,Shenzhen 518126,China

The online monitoring, distributed fault location and cable online monitoring equipment for power transmission and distribution lines launched by SHENZHEN DINSEE SMART TECHNOLOGY CO.,LTD. has been widely used in Southern Power Grid and State Grid, and has achieved good results.

Record No.: Yue ICP Bei 2022070794-1 | Website Map XML Map

主站蜘蛛池模板: 日韩精品国产另类专区| 欧美国产成人精品一区二区三区| 99久久国语露脸精品国产| 成人亚洲综合av天堂| 超碰97人人射妻| 国产农村妇女高潮大叫| 久久996re热这里有精品| 青青青国产最新视频在线观看| 亚洲另类伦春色综合| 色丁香婷婷综合久久| 99精品国产福利一区二区| 国产亚洲精品久久yy5099 | 日韩精品一区二区三区中文无码| 九九视频在线观看视频6| 成人av片无码免费网站| 加勒比色老久久综合网| 亚洲级αv无码毛片久久精品| 中文无码不卡人妻在线看| 亚洲制服丝袜精品久久| 三级特黄60分钟在线观看| 99亚洲乱人伦aⅴ精品| 国产精品视频分类精品| 中国做爰国产精品视频| 东京热一本无码av| 性一交一乱一伦一色一情孩交| 亚洲成年看片在线观看| 久久99精品久久久久免费| 99re久久精品国产首页| 国产毛a片久久久久无码| 国产一精品一av一免费| 开心五月色婷婷综合开心网| 欧美又黄又大又爽a片三年片| 99久久精品国产免费看| 狠狠色噜噜狠狠狠狠97| 亚洲熟悉妇女xxx妇女av| 国产精品免费无码二区| 伊人精品无码av一区二区三区 | 一本久久a久久免费精品不卡| 中文无码vr最新无码av专区| 亚洲精品无码av专区最新| 日韩在线 | 中文|